Doing a good job in the maintenance and maintenance of the capsule filling machine can prolong the service life of the machine, and the direction of maintenance and maintenance should be found to minimize the maintenance cost and make the machine run stably for a long time. Here's what I know and recommend for the maintenance of the capsule filling machine and its core drive cam splitter. If there is a mistake, please criticize and correct it.
(1) When the machine works normally for a long time, the parts that are in direct contact with the drug should be cleaned regularly, and when the drug batch is changed or the service is out for a long time, it should also be cleaned.
(2) Transmission components such as lifting rotary cam indexer under the working surface of the machine should be added with an appropriate amount of lubricating oil (grease) to reduce the wear of moving parts.
(3) The cam indexing table responsible for transmission should check the oil quantity once a month, refuel in time when it is insufficient, and replace the lubricating oil once every six months; The lubricating oil should be replaced once every 3000h of operation, and 90# engine oil is generally used.

(4) The safety clutch plays a protective role when the machine is overloaded, and the clutch should not slip when the load is normal, but the phenomenon of slipping may occur due to long-term use, and when the slipping phenomenon occurs during normal use, the round nut of the clutch can be tightened to ensure the normal operation of the machine and play a protective role.
(5) The vacuum separator of the vacuum system mainly plays the role of sucking the cap into the upper and lower modules and separating the cap and body in the filling of the hard cap, if the capsule can not be separated from the cap and the body, the subsequent filling will not be carried out. For every 1 station of the machine's turntable, the machine spindle rotates for 1 cycle, and the vacuum separator moves up and down once under the action of the lifting cam indexer. If the separation of cap cap and body is not smooth, the gap between the upper plane of the vacuum separator and the lower plane of the lower module should be checked, the gap is too large so that the vacuum degree of the vacuum system cannot reach the vacuum degree required by the separation of cap and body (about 0.05MPa), and the gap is too small and it is easy to produce a collision to deform the lower module.