The positioning accuracy of the cam divider may decrease due to a variety of factors. The following are common reasons and detailed analysis:
1. Mechanical wear
Cam and roller wear: After long-term operation, the wear of the cam profile or roller surface will cause the contact gap to increase, and return error or shaking will occur during transmission.
Bearing wear: After the bearing supporting the divider turntable is worn, the radial or axial clearance increases, which directly affects the positioning stability.
Solution: Check the wear condition regularly, replace high hardness/wear-resistant materials (such as carburized steel rollers), or use lubrication measures to reduce wear.
2. Assembly error
Concentricity/parallelism deviation: The input shaft (drive end) and the output shaft (load end) are not installed concentrically, or the coupling is poorly aligned, resulting in additional stress or vibration.
Loose fasteners: Insufficient bolt preload may cause structural micro-motion and cumulative errors.
Solution: Use a laser alignment instrument for calibration and check the fastener torque regularly.
3. Poor lubrication
Lubricant failure: Grease drying or contamination will increase friction and cause uneven movement.
Improper lubrication method: For example, high-temperature resistant grease should be selected under high-speed conditions.
Solution: Replace lubricants periodically as required by the manual, and use synthetic grease for high-temperature environments.
4. Load change
Inertia force influence: Excessive load inertia or sudden acceleration and deceleration may cause the cam and roller to instantly lose contact ("tooth jump").
Eccentric load problem: The center of gravity of the load deviates from the axis of the divider, generating additional torque.
Solution: Recalculate the load inertia and increase the reduction ratio or balancing device if necessary.

5. Elastic deformation
Insufficient transmission chain stiffness: For example, when the synchronous belt is driven, the belt stretching will cause hysteresis error.
Structural deformation: Poor frame rigidity may amplify vibration.
Solution: Use direct drive (such as servo motor + coupling) or reinforce the frame.
6. Increased backlash
Gear/chain transmission pair wear: When driven indirectly, backlash accumulation will affect the output accuracy of the divider.
Solution: Replace the anti-backlash gear or use a preloaded structure.
7. Environmental factors
Temperature change: Thermal expansion and contraction of metals may change the clearance of key components.
Pollution: Dust and chips invade the cam groove and interfere with the movement of the roller.
Solution: Add a protective cover or use stainless steel to resist corrosion.
8. Improper design or selection
The number of divider stations does not match the accuracy: For example, a coarse indexing model is selected for high-precision scenarios (such as 8 stations is better than 6 stations).
Insufficient dynamic accuracy: The acceleration impact during start-stop was not considered during selection.
Solution: Reselect to ensure that the static accuracy (such as ±30 arcsec) and dynamic performance meet the standards.