Clinical chemistry analyzer: applications, working principle, and main functions

Nov 21, 2026 Leave a message

Dr. Emily Carter
Dr. Emily Carter
As a leading technical expert at Hansheng Automation, Dr. Carter specializes in the R&D of next-generation intelligent electric actuators and control solutions. Her work focuses on integrating cutting-edge technology to enhance the performance and reliability of our gear reducers.

 

A clinical chemistry analyzer is a laboratory instrument used to measure the concentrations of specific chemical substances in biological samples such as serum, plasma, and urine. It uses optical and electrochemical measurement methods, depending on the instrument's configuration. Common tests include glucose, urea, creatinine, cholesterol, and various enzyme assays. Some analyzers are also equipped to measure electrolytes such as sodium, potassium, and chloride.

Main applications of clinical chemistry analyzers

Clinical chemistry analyzers are used to measure biochemical indicators in human samples. The results provide laboratory data that support disease diagnosis, treatment monitoring, and health assessment.

In hospital laboratories and clinical testing facilities, these analyzers are commonly used for liver function, kidney function, blood glucose, blood lipids, and electrolyte tests. Doctors interpret the results alongside other clinical information to assess organ function, investigate possible health conditions, and monitor changes during treatment.

Clinical chemistry analyzers are widely used in general hospitals, specialist hospitals, medical testing laboratories, and other healthcare facilities. Their testing capabilities and supported assays depend on the instrument model and configuration.

Working principle of clinical chemistry analyzers

Clinical chemistry analyzers mainly use optical and electrochemical measurement methods. Photometric analysis is one of the common methods used in clinical chemistry testing.

Photometric analysis (colorimetry)

In photometric analysis, the analyzer mixes a measured volume of sample with the appropriate reagent according to the test procedure. The target substance reacts with the reagent, producing a color change or a change in turbidity.

The analyzer then directs light at a specific wavelength through the reaction mixture. A photodetector measures the absorbance or another optical signal produced during the reaction. Under the conditions of the analytical method, this signal has a quantitative relationship with the concentration of the target substance. The analyzer uses the relevant calibration data to calculate the concentration in the sample.

Depending on the reaction and calculation method, photometric testing can use endpoint or rate analysis. Endpoint methods calculate the result from the signal measured at a specified stage of the reaction. Rate methods measure changes in the signal over time to determine the concentration of the target substance.

Ion-selective electrode method (ISE)

Some clinical chemistry analyzers include an ion-selective electrode (ISE) module for measuring electrolytes such as sodium, potassium, and chloride. This method uses ion-selective electrodes to detect changes in electrical potential associated with specific ions. The analyzer processes the measured potential to determine the corresponding ion concentration.

Not all clinical chemistry analyzers include an ISE module. Its availability depends on the instrument design and configuration.

Main functions of fully automated clinical chemistry analyzers

Fully automated clinical chemistry analyzers use several coordinated modules to process samples and complete tests. Automation reduces repetitive manual operations and improves laboratory sample processing efficiency. The specific module arrangement and level of automation vary between models.

Sample handling

The analyzer manages samples through components such as sample racks, barcode identification systems, and sampling probes. It aspirates the required sample volume according to the test procedure. Some systems also support continuous sample loading and priority processing of emergency samples.

Reagent dispensing

The reagent system automatically aspirates and dispenses the required reagents according to the selected test and reaction procedure. The analyzer controls the dispensing volume and sequence to meet the requirements of different assays.

Mixing and reaction monitoring

The sample and reagents are mixed according to the programmed procedure. The reaction takes place under specified temperature and operating conditions. The reaction system monitors the optical or electrochemical signals generated during the process.

Result calculation and data management

After measurement, the analyzer's control software calculates the results using the measured signals and calibration data. The system also records and manages test information. Depending on the instrument configuration, it may support result transmission and connection to a laboratory information system (LIS).

In routine operation, test results also depend on reagent quality, calibration status, internal quality control, sample condition, and instrument maintenance. Regular calibration and quality control help monitor analytical performance and identify potential sources of error.

Clinical chemistry analyzer applications and custom component machining

Clinical chemistry analyzers use optical and electrochemical methods to quantify a range of biochemical indicators. Their testing capacity and level of automation depend on the model, measurement modules, and reagent system. Hospitals and medical laboratories select equipment according to their testing requirements, sample workload, and operating conditions.

For non-standard mechanical parts and functional components used in testing equipment and related automated machinery, we provide precision machining based on customer-supplied engineering drawings. The machining process is selected according to the part structure and specified manufacturing requirements.

Hansheng Automation also provides custom machining services for precision components used in other industries. Our work covers yacht components, remote-control racing car parts, tobacco packaging machinery components, and filling machinery parts. We support drawing-based production of non-standard components for different equipment manufacturing and assembly requirements.

Amusement--Stage-Machinery